Loading "flash:/c2950-i6q4l2-mz.121-22.EA4.bin"... ######################### [OK] Restricted Rights Legend
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software - Restricted Rights clause at FAR sec. 52.227-19 and subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95134-1706
Cisco Internetwork Operating System Software IOS (tm) C2950 Software (C2950-I6Q4L2-M), Version 12.1(22)EA4, RELEASE SOFTWARE(fc1) Copyright (c) 1986-2005 by cisco Systems, Inc. Compiled Wed 18-May-05 22:31 by jharirba
Cisco WS-C2950-24 (RC32300) processor (revision C0) with 21039K bytes of memory. Processor board ID FHK0610Z0WC Running Standard Image 24 FastEthernet/IEEE 802.3 interface(s)
63488K bytes of flash-simulated non-volatile configuration memory. Base ethernet MAC Address: 00E0.8F81.5658 Motherboard assembly number: 73-5781-09 Power supply part number: 34-0965-01 Motherboard serial number: FOC061004SZ Power supply serial number: DAB0609127D Model revision number: C0 Motherboard revision number: A0 Model number: WS-C2950-24 System serial number: FHK0610Z0WC
Cisco Internetwork Operating System Software IOS (tm) C2950 Software (C2950-I6Q4L2-M), Version 12.1(22)EA4, RELEASE SOFTWARE(fc1) Copyright (c) 1986-2005 by cisco Systems, Inc. Compiled Wed 18-May-05 22:31 by jharirba
Press RETURN to get started!
%LINK-5-CHANGED: Interface FastEthernet0/1, changed state to up
%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to up
Switch>en Switch#conf t Enter configuration commands, one per line. End with CNTL/Z. NorthPole(config)#hostname NorthPole NorthPole(config)# NorthPole(config)#enable secret santa NorthPole(config)#ser NorthPole(config)#service pa NorthPole(config)#service password-encryption NorthPole(config)#exit NorthPole(config)#ban NorthPole(config)#banner motd NorthPole(config)#banner motd #Ho Ho Ho!# NorthPole(config)#priv NorthPole(config)#privilege co NorthPole(config)#privilege configure le NorthPole(config)#privilege configure level 15 whiteman NorthPole(config)#exi NorthPole(config)#exit NorthPole# %SYS-5-CONFIG_I: Configured from console by console
NorthPole#sh r NorthPole#sh running-config Building configuration...
Current configuration : 1050 bytes ! version 12.1 no service timestamps log datetime msec no service timestamps debug datetime msec service password-encryption ! hostname NorthPole ! enable secret 5 $1$mERr$d3A0.gvt/JPfxbM.FrZMf0 ! ! ! spanning-tree mode pvst ! interface FastEthernet0/1 ! interface FastEthernet0/2 ! interface FastEthernet0/3 ! interface FastEthernet0/4 ! interface FastEthernet0/5 ! interface FastEthernet0/6 ! interface FastEthernet0/7 ! interface FastEthernet0/8 ! interface FastEthernet0/9 ! interface FastEthernet0/10 ! interface FastEthernet0/11 ! interface FastEthernet0/12 ! interface FastEthernet0/13 ! interface FastEthernet0/14 ! interface FastEthernet0/15 ! interface FastEthernet0/16 ! interface FastEthernet0/17 ! interface FastEthernet0/18 ! interface FastEthernet0/19 ! interface FastEthernet0/20 ! interface FastEthernet0/21 ! interface FastEthernet0/22 ! interface FastEthernet0/23 ! interface FastEthernet0/24 ! interface Vlan1 no ip address shutdown ! banner motd ^CHo Ho Ho!^C ! ! ! line con 0 ! line vty 0 4 login line vty 5 15 login ! ! end